WeChat: +86 18368780285          Email: info@abimat-electric.com

Pillar surge arrester

At present, the overhead insulation process is fast in urban and rural areas below 10kV, but there are many connecting parts such as switches, lightning arresters, connection clips, and pillars in the pole distribution transformer area, which have brought about a series of problems such as multiple operation failure points, poor insulation safety protection conditions, complicated installation, difficult maintenance and high cost, and poor live working conditions. In order to deal with the above problems, it is necessary to reform some equipment and line connection of the rod distribution system, so as to simplify the device and further increase the purpose of operation safety. HY5WBG-17/50 composite zinc oxide arrester device has four functions: pillar function, lightning arrester function, piercing power function, electrical grounding function, with a multi-purpose structure. The use of this device can also reduce one lightning arrester cross arm (because of the use of the strut cross arm that would otherwise be needed); Three insulators for reducing the lower vertical line fixation; That is, to reduce seven peeling points, reduce construction hours, and reduce six fault points, it can achieve the purpose of simplifying the line device, further increasing the safety and reliability of operation, and making the line more concise and beautiful. In addition, this device integrates a variety of functions, the original need for seven peeling points of insulation and insulation in one place, and the insulation cover design is reasonable, can be straight to achieve full insulation, creating favorable conditions for safety and live work.

Technology parameter:

Arrester type

Rated voltage (kV)

Nominal voltage (kV)

Continuous Operating (kV)

Dc 1mA reference voltage
(kV)

lightning impulse current Peak residual voltage  (kV)≯

Lightning impact 2ms square Wave current A

High current pressure release Expected symmetrical current (kA)

Bending strength (N)

HY5WBG-17/50

17

10

13.6

25

50

100

25

>1000

HY5WBG-17/50T

17

10

13.6

25

50

100

25

>1000

HY5WDG-17/50

17

10

13.6

25

50

100

25

>1000

HY5WDG-17/50T

17

10

13.6

25

50

100

25

>1000

HY5WDG-34/90

34

24

27.2

50

90

250

50

>1000

HY5WDG-34/90T

34

24

27.2

50

90

250

50

>1000

 

Note: According to the above table, the new pillar lightning protection device can reduce 9 peeling points, reduce construction hours, and reduce 6 connection failure points, which can achieve simplified installation, further increase the purpose of safe and reliable operation, and make the line more concise and beautiful.

Product characteristics:

1, The core and jacket of the arrester are molded to become a dense whole without cavities, eliminating the moisture absorption caused by respiration and fundamentally eliminating the accidents caused by moisture on the arrester chip;

2, the lightning arrester adopts a special strengthening structure, so that it has good mechanical properties, can double as an insulator;

3, the lightning arrester synthetic jacket is made of silicone rubber material, so that it has strong anti-pollution performance and good explosion-proof performance. In addition, light weight, long service life;

4, The arrester is designed and produced according to class III heavy pollution, and the minimum creepage specific distance of the insulation jacket is 25mmkV and the creepage distance is 320mm;

5, The overall structure of the arrester is optimized and has the combined function.

(1) Both grounding stem, can meet the needs of electrical inspection and grounding, can simplify the tower device.

(2) Special strengthening structure, so that it has good mechanical properties, can be used as a pillar insulator.

(3) The connection terminal block can segment the cable fault, reduce the power failure range, and has the breaking function of the knife brake.

(4) The arrester adopts full insulation design, which can effectively avoid the occurrence of external damage and other accidents.

6, the HY5WDG-17/50T arrester device has the function of pillar, connection terminal bus wiring function, electrical grounding function, which the connection terminal bus can segment cable fault, reduce the power outage range, with the tool brake segment function.

Contact Us:

Email: info@abimat-electric.com
WeChat: +86 18368780285

Leave Your Message: