polymer Lightning arrester

Abimat Electric polymer arrester is polymer housed Metal Oxide arrester. We produce Discharging current 5kA and 10kA surge arrester, rated voltage from 3kV to 36kV.

polymer lightning arrester PARAMERTERS:

TypeRated voltagemax. continuous operation voltage MCOVmax. Residual voltage (kV)2000μs rectangular current impulse withstand 4/10μs high current impulse withstand
1/4μs steep current impulse8/20μs lightning current impulse30/60μs switching current impulse
Discharging current 5kA
YH5W-33kV (rms)2.55kV (rms)11.3KV (crest)9KV (crest)8.9KV (crest)150A 65kA (crest)
YH5W-66kV (rms)5.1kV (rms)22.6KV (crest)18KV (crest)16.8KV (crest)150A 65kA (crest)
YH5W-99kV (rms)7.65kV (rms)33.7KV (crest)27KV (crest)23.8KV (crest)150A 65kA (crest)
YH5W-1010kV (rms)8.4kV (rms)36KV (crest)30KV (crest)23KV (crest)150A 65kA (crest)
YH5W-1111kV (rms)9.4kV (rms)40KV (crest)33KV (crest)30KV (crest)150A 65kA (crest)
YH5W-1212kV (rms)10.2kV (rms)42.2KV (crest)36KV (crest)27KV (crest)150A 65kA (crest)
YH5W-1515kV (rms)12.7kV (rms)51KV (crest)45KV (crest)38.5KV (crest)150A 65kA (crest)
YH5W-1818kV (rms)15.3kV (rms)61.5KV (crest)54KV (crest)46.2KV (crest)150A 65kA (crest)
YH5W-2121kV (rms)17kV (rms)71.8KV (crest)63KV (crest)54.2KV (crest)150A 65kA (crest)
YH5W-2424kV (rms)19.5kV (rms)82KV (crest)72KV (crest)62KV (crest)150A 65kA (crest)
YH5W-2727kV (rms)22kV (rms)92KV (crest)81KV (crest)69.8KV (crest)150A 65kA (crest)
YH5W-3030kV (rms)24.4kV (rms)102KV (crest)90KV (crest)79KV (crest)150A 65kA (crest)
YH5W-3333kV (rms)27.5kV (rms)112KV (crest)99KV (crest)86.7KV (crest)150A 65kA (crest)
YH5W-3636kV (rms)29kV (rms)123KV (crest)108KV (crest)92.4KV (crest)150A 65kA (crest)
 
Discharging current 10kA
YH10W-33kV (rms)2.55kV (rms)10.3KV (crest)8KV (crest)8.1KV (crest)250A100kA (crest)
YH10W-66kV (rms)5.1kV (rms)20.5KV (crest)16KV (crest)15.5KV (crest)250A100kA (crest)
YH10W-99kV (rms)7.65kV (rms)31KV (crest)25KV (crest)22KV (crest)250A100kA (crest)
YH10W-1010kV (rms)8.4kV (rms)33KV (crest)27KV (crest)24KV (crest)250A100kA (crest)
YH10W-1111kV (rms)9.4kV (rms)36.4KV (crest)30KV (crest)27.5KV (crest)250A100kA (crest)
YH10W-1212kV (rms)10.2kV (rms)38.5KV (crest)33KV (crest)29KV (crest)250A100kA (crest)
YH10W-1515kV (rms)12.7kV (rms)46.5KV (crest)41KV (crest)35KV (crest)250A100kA (crest)
YH10W-1818kV (rms)15.3kV (rms)56KV (crest)49KV (crest)42.5KV (crest)250A100kA (crest)
YH10W-2121kV (rms)17kV (rms)65KV (crest)57KV (crest)49.5KV (crest)250A100kA (crest)
YH10W-2424kV (rms)19.5kV (rms)75KV (crest)65KV (crest)56KV (crest)250A100kA (crest)
YH10W-2727kV (rms)22kV (rms)84KV (crest)74KV (crest)63.5KV (crest)250A100kA (crest)
YH10W-3030kV (rms)24.4kV (rms)93KV (crest)82KV (crest)72KV (crest)250A100kA (crest)
YH10W-3333kV (rms)27.5kV (rms)101KV (crest)90KV (crest)79KV (crest)250A100kA (crest)
YH10W-3636kV (rms)29kV (rms)112KV (crest)98KV (crest)84KV (crest)250A100kA (crest)

*OEM and custom size are available

*The shed numbers and terminals could be changed according to requirements

POLYMER LIGHTNING ARRESTER usage & feature:

Polymer lightning arrester is the basis of insulation coordination of all kinds of electrical equipment (transformer, reactor, capacitor, generator, engine, PT, CT, circuit breaker, contactor, etc.) in power system. Polymer lightning arrester is the most advanced product of conventional surge arrester in the world. The core working element of this product is fired with zinc oxide based polymetallic oxide powder. It has excellent nonlinear shape and volt ampere characteristics, corresponding fast steep wave and large flow capacity. Abimat surge arrester is mainly used in power system all types of electrical equipment. The color and size of the product can be customized. Please contact us if you want to purchase more types of surge arrester.

POLYMER LIGHTNING ARRESTER using environments:

  • Ambient temperature range -40℃~+40℃;
  • Above sea level no higher than 1000m;
  • Power frequency is 48-62HZ;
  • Continuous power frequency voltage on the lightning arrester no higher than continuous working voltage of lightning arrester;
  • Utmost wind velocity no higher than 35m/s;
  • Area where earthquake intensity less than 7 degree;
  • Messy area should be indicated.