Station lightning arrester
Station lightning arrester is a device designed to protect electrical equipment and installations from damage caused by lightning strikes. It functions by diverting the high voltage currents generated during a lightning strike safely to the ground, thus preventing damage to sensitive equipment and ensuring the safety of personnel. These arresters are typically installed at strategic points within electrical substations or stations to mitigate the risks associated with lightning-induced surges in power distribution systems.

Gapless surge arrester | ||||||||||
System nominal voltage (kV) | Arrester Type | Rated voltage (kV) | Arrester continuous operating voltage (kV) | Dc 1mA reference voltage (kV) | Maximum leakage at 0.75x DC 1mA voltage (μA) | Peak residual voltage (kV)≯ | 2000 μs square wave current capacity (A) | 4/10 high current impulse withstand (kV) | ||
8/20 lightning impulse current | 30/60 operation impulse current | 1/4 steep impulse current | ||||||||
3 | (HY)YH5WZ-3.8/13.5 | 3.8 | 2 | 7.2 | 50 | 12 | 11.5 | 15.5 | 200 | 65 |
3 | (HY)YH5WZ-5/13.5 | 5 | 4 | 7.2 | 50 | 13.5 | 11.5 | 15.5 | 200 | 65 |
6 | (HY)YH5WZ-7.6/27 | 7.6 | 4 | 14.4 | 50 | 27 | 23 | 31 | 200 | 65 |
6 | (HY)YH5WZ-10/27 | 10 | 8 | 14.4 | 50 | 27 | 23 | 31 | 200 | 65 |
10 | (HY)YH5WZ-12.7/45 | 12.7 | 6.6 | 24 | 50 | 45 | 38.3 | 51.8 | 200 | 65 |
10 | (HY)YH5WZ-17/45 | 17 | 13.6 | 24 | 50 | 45 | 38.3 | 51.8 | 200 | 65 |
35 | (HY)YH5WZ-51/134 | 51 | 40.8 | 73 | 50 | 134 | 114 | 154 | 400 | 65 |
35 | (HY)YH5WZ-42/134 | 42 | 23.4 | 73 | 50 | 134 | 114 | 154 | 400 | 65 |
66 | (HY)YH5WZ-84/221 | 84 | 67.2 | 121 | 50 | 221 | 188 | 254 | 600 | 65 |
66 | (HY)YH5WZ-90/235 | 90 | 72.5 | 130 | 50 | 235 | 201 | 270 | 600 | 65 |
66 | (HY)YH10WZ-84/221 | 94 | 67.5 | 121 | 50 | 221 | 188 | 248 | 600 | 100 |
66 | (HY)YH10WZ-90/235 | 90 | 72.5 | 130 | 50 | 235 | 201 | 264 | 600 | 100 |
110 | (HY)YH5WZ-100/260 | 100 | 78 | 145 | 50 | 260 | 221 | 299 | 600 | 65 |
110 | (HY)YH5WZ-102/266 | 102 | 79.6 | 148 | 50 | 266 | 226 | 305 | 600 | 65 |
110 | (HY)YH5WZ-108/281 | 108 | 84 | 157 | 50 | 281 | 239 | 323 | 600 | 65 |
110 | (HY)YH10WZ-100/260 | 100 | 78 | 145 | 50 | 260 | 221 | 291 | 600 | 100 |
110 | (HY)YH10WZ-102/266 | 1032 | 79.6 | 148 | 50 | 266 | 226 | 297 | 600 | 100 |
110 | (HY)YH10WZ-108/281 | 108 | 157 | 157 | 50 | 281 | 239 | 315 | 600 | 100 |
220 | (HY)YH10WZ-192/500 | 192 | 150 | 280 | 50 | 500 | 426 | 560 | 800 | 100 |
220 | (HY)YH10WZ-200/520 | 200 | 156 | 290 | 50 | 520 | 442 | 582 | 800 | 100 |
220 | (HY)YH10WZ-204/532 | 204 | 159 | 296 | 50 | 532 | 452 | 594 | 800 | 100 |
220 | (HY)YH10WZ2-16/562 | 216 | 168.5 | 314 | 50 | 562 | 478 | 630 | 800 | 100 |
Series gap surge arrester | ||||||||||
System nominal voltage (kV) | Arrester Type | Rated voltage (kV) | Power frequency discharge voltage (kV) ≮ | 1.2/50 impulse discharge voltage (kV) peak value ≯ | Maximum conducting current (μA) | Peak residual voltage (kV)≯ | 2000 μs square wave current capacity (A) | 4/10 high current impulse withstand (kV) | ||
8/20 lightning impulse current | 30/60 operation impulse current | 1/4 steep impulse current | ||||||||
3 | (HY)YH5CZ-3.8/12.0 | 3.8 | 8 | 12 | 20 | 12 | 10.2 | 13.5 | 200 | 65 |
6 | (HY)YH5CZ-7.6/24 | 7.6 | 16 | 24 | 20 | 24 | 20.4 | 27 | 200 | 65 |
10 | (HY)YH5CZ-12.7/41 | 12.7 | 26 | 41 | 20 | 45 | 35 | 46 | 200 | 65 |
35 | (HY)YH5CZ-42/124 | 42 | 80 | 124 | 20 | 124 | 100 | 143 | 400 | 65 |