Surgearrester for line

Surge arrester for a power line is a protective device installed in electrical distribution systems to mitigate the impact of voltage surges and transient overvoltages. It operates by diverting excess electrical energy to ground when the voltage exceeds a predefined threshold, thereby safeguarding the integrity of the electrical infrastructure and connected equipment. This device is essential in ensuring the reliability and longevity of power lines by preventing damage that could result from unpredictable electrical disturbances.

technical parameters of Line type surge arrester:

Gapless surge arrester
System nominal voltage (kV) Arrester Type Rated voltage (kV) Arrester continuous operating voltage (kV) Dc 1mA reference voltage (kV)  Maximum leakage at 0.75x DC 1mA voltage (μA) Peak residual voltage  (kV)≯ 2000 μs square wave current capacity (A) 4/10  high current impulse withstand (kV)
8/20 lightning impulse current  30/60 operation impulse current 1/4 steep impulse current
35 (HY)YH5WX-51/134 51 40.8 73 50 134 114 154 400 65
35 (HY)YH5WX-54/150 54 43.2 77 50 150 128 169 400 65
66 (HY)YH5WX-96/250 96 75 140 50 260 221 299 600 65
66 (HY)YH5WX-96/275 96 75 154 50 275 234 316 600 65
110 (HY)YH5WX-108/281 108 84 157 50 281 239 323 600 65
110 (HY)YH5WX-108/309 108 84 173 50 309 263 348 600 65
110 (HY)YH10WX-108/281 108 84 157 50 281 239 315 600 100
110 (HY)YH10WX-108/309 108 84 173 50 309 263 348 600 100
Series gap surge arrester
System nominal voltage (kV) Arrester Type Rated voltage (kV) Power frequency discharge voltage (kV)  ≮ 1.2/50 impulse discharge voltage (kV) peak value ≯ Maximum conducting current (μA) Peak residual voltage  (kV)≯ 2000 μs square wave current capacity (A) 4/10  high current impulse withstand (kV)
8/20 lightning impulse current 30/60 operation impulse current 1/4 steep impulse current
35 (HY)YH5CX-42/120 42 80 120 20 120 100 138 400 –
35 (HY)YH5CX-42/150 42 80 150 20 150 128 169 400 –
66 (HY)YH5CX-75/218 75 117* 117* 20 218 – 246 600 65
110 (HY)YH5CX-90/260 90 170* 260 20 260 – 292 600 65
110 (HY)YH10CX-90/260 90 170* 20 20 260 – 292 600 100
110 (HY)YH10CX-90/280 96 170* 280 20 280 – 314 600 100
110 (HY)YH10CX-102/296 102 170* 296 20 296 – 332 600 100